Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-12 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	34
Date	08/12/14
Start Time	10:26:51
Diameter Midpoint
 10.9	620.424
 11.3	4453.24
 11.8	36050.2
 12.2	53268.6
 12.6	65359.6
 13.1	81825.9
 13.6	106439
 14.1	124933
 14.6	153028
 15.1	178860
 15.7	211744
 16.3	246954
 16.8	284014
 17.5	323568
 18.1	370062
 18.8	415933
 19.5	466947
 20.2	515238
 20.9	552787
 21.7	612973
 22.5	670763
 23.3	719541
 24.1	772900
 25.0	819905
 25.9	876446
 26.9	916991
 27.9	959344
 28.9	991765
 30.0	1.00523e+006
 31.1	1.0113e+006
 32.2	1.00435e+006
 33.4	974674
 34.6	935972
 35.9	880088
 37.2	815366
 38.5	742791
 40.0	664513
 41.4	574820
 42.9	493002
 44.5	403580
 46.1	327866
 47.8	261774
 49.6	202740
 51.4	155061
 53.3	114588
 55.2	82552.4
 57.3	59392.3
 59.4	41309.4
 61.5	28026.2
 63.8	18590
 66.1	12429.5
 68.5	8282.95
 71.0	5493.16
 73.7	3609.12
 76.4	2312.1
 79.1	1582.13
 82.0	1089.85
 85.1	795.967
 88.2	586.357
 91.4	401.571
 94.7	312.733
 98.2	254.104
101.8	208.449
105.5	170.62
109.4	136.185
113.4	159.97
117.6	146.325
121.9	161.221
126.3	106.002
131.0	128.181
135.8	99.7755
140.7	87.837
145.9	102.026
151.2	94.9464
156.8	113.758
162.5	83.8347
168.5	90.5922
174.7	92.8043
181.1	92.128
187.7	68.66
194.6	91.5524
201.7	71.7814
209.1	91.6366
216.7	74.3144
224.7	85.7031
232.9	51.101
241.4	58.3212
250.3	55.9267
259.5	55.4325
269.0	64.6355
278.8	44.8098
289.0	56.787
299.6	35.3894
310.6	32.9603
322.0	39.8666
333.8	22.0526
346.0	29.6761
358.7	14.525
371.8	26.7908
385.4	32.0608
399.5	20.7538
414.2	17.1246
429.4	17.9975
445.1	9.57428
461.4	14.6475
478.3	11.4087
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.1916
High Voltage	9851.08
Lower Size(nm)	10.7461
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1076.23
Median(nm)	29.0678
Mean(nm)	29.8921
Geo. Mean(nm)	28.4461
Mode(nm)	31.059
Geo. Std. Dev.	1.37474
Total Concentration(#/cm)	2.23707e+007
Comment	